Results 1 - 20 de 25
Filter
1.
Rev. baiana enferm ; 37: e52988, 2023. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1529691

ABSTRACT

Objetivos: descrever as boas práticas realizadas pela equipe multiprofissional durante a aspiração de vias aéreas inferiores em pacientes adultos, internados na Unidade de Terapia Intensiva. Método: estudo quantitativo, observacional, descritivo e prospectivo, norteado pela ferramenta STROBE, realizado em uma Unidade de Terapia Intensiva adulto, entre maio e agosto de 2022. A amostra foi composta por 25 observações e a coleta de dados através de checklist, incluídos os profissionais de enfermagem, fisioterapia e medicina. Os dados foram processados no Statistical Package for the Social Sciences, sendo calculadas as frequências absolutas e relativas. Resultados: a maioria das aspirações foram realizadas pela equipe de enfermagem, 20 (80%) profissionais não regularam a fração inspirada de oxigênio antes e após o procedimento, 06 (60%) profissionais não clampearam a sonda durante a sua inserção. O uso de máscara (100%), capote (92%) e luva (100%) foram as boas práticas com maior aderência entre os participantes. Conclusão: reforça-se a necessidade de incentivar os treinamentos abordando as boas práticas durante a aspiração endotraqueal.


Objetivos: describir las buenas prácticas realizadas por el equipo multiprofesional durante la aspiración de vías aéreas inferiores en pacientes adultos, ingresados en la Unidad de Cuidados Intensivos. Método: estudio cuantitativo, observacional, descriptivo y prospectivo, guiado por la herramienta STROBE, realizado en una unidad de cuidados intensivos adulta, entre mayo y agosto de 2022. La muestra fue compuesta por 25 observaciones y la recogida de datos a través de checklist, incluidos los profesionales de enfermería, fisioterapia y medicina. Los datos fueron procesados en el Statistical Package for the Social Sciences, siendo calculadas las frecuencias absolutas y relativas. Resultados: la mayoría de las aspiraciones fueron realizadas por el equipo de enfermería, 20 (80%) profesionales no regularon la fracción inspirada de oxígeno antes y después del procedimiento, 06 (60%) profesionales no clampearon la sonda durante su inserción. El uso de máscara (100%), capucha (92%) y guante (100%) fueron las mejores prácticas con mayor adherencia entre los participantes. Conclusión: se refuerza la necesidad de incentivar los entrenamientos abordando las buenas prácticas durante la aspiración endotraqueal.


Objective: to describe the good practices performed by the multiprofessional team during lower airway aspiration in adult patients admitted to the Intensive Care Unit. Method: quantitative, observational, descriptive and prospective study, guided by the STROBE tool, conducted in an adult intensive care unit, between May and August 2022. The sample consisted of 25 observations and data collection through checklist, including nursing, physiotherapy and medicine professionals. The data were processed in the Statistical Package for the Social Sciences, and the absolute and relative frequencies were calculated. Results: most aspirations were performed by the nursing team, 20 (80%) professionals did not regulate the inspired fraction of oxygen before and after the procedure, 06 (60%) professionals did not clamp the tube during its insertion. The use of mask (100%), cloak (92%) and glove (100%) were the best practices with greater adherence among participants. Conclusion: there is the need to encourage training addressing good practices during endotracheal aspiration.


Subject(s)
Humans , Male , Female , Suction/methods , Practice Guideline , Airway Management/methods , Intubation, Intratracheal/nursing
2.
Rev. bras. educ. méd ; 47(3): e104, 2023. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1507847

ABSTRACT

Resumo: Introdução: A intubação orotraqueal é um procedimento importante no manejo da via aérea, principalmente quando realizada em situações de emergência. A videolaringoscopia é um artificio que facilita a visualização da glote ao auxiliar a intubação. Objetivo: Este estudo teve como objeto acoplar uma câmera de vídeo a um laringoscópio convencional do tipo Macintosh para possibilitar e orientar o treinamento da intubação orotraqueal. Método: O uso de uma câmera acoplada a um laringoscópio convencional permite a visibilização direta e indireta da glote. As imagens da câmera podem ser transmitidas por wi-fi e compartilhadas para dispositivos e plataformas eletrônicos, visando ao ensino presencial ou remoto da intubação orotraqueal. Resultado: A utilização do dispositivo artesanal como método de ensino de intubação orotraqueal permite ao docente ensinar a teoria do procedimento e orientar e corrigir a execução realizada pelo acadêmico. Esse feedback no treinamento prático pode ser realizado presencialmente ou por via remota. Conclusão: O uso do dispositivo artesanal de videolaringoscopia no ensino médico é uma ferramenta de baixo custo para aperfeiçoar o treinamento de intubação orotraqueal convencional.


Abstract: Introduction: The orotracheal intubation is an important procedure in airway management, especially when performed in emergency situations. Video-laryngoscopy is an artifice that facilitates visualization of the glottis, aiding intubation. Objective: This study aimed to attach a video camera to a conventional Macintosh-type laryngoscope to enable and train intubation or otracheal training. Method: The use of a camera coupled to a conventional laryngoscope allows direct and indirect visualization of the glottis. Camera images can be transmitted over wi-fi and shared to electronic devices and platforms, aiming at teaching in person or remotely about orotracheal intubation. Result: The use of the device as a method of teaching intubation or otracheal, allows teaching to teach the theory of procedure and training the execution performed by the artisanal method. This feedback in the practical training of orotracheal intubation in mannequins can be performed in person or remotely. Conclusion: The use of handcrafted video laryngoscopy device in medical education is a low-cost tool to improve conventional orotracheal intubation training.

3.
MedUNAB ; 25(3): [492-498], 01-12-2022.
Article in Spanish | LILACS | ID: biblio-1436139

ABSTRACT

Introducción. El manejo de la vía aérea difícil anticipada es un reto anestésico que supone la valoración preoperatoria de las características anatómicas y los factores de riesgo específicos del paciente. La intubación difícil se presenta en 1.6 de 1,000 eventos y la intubación fallida en 0.06 de 1,000 eventos. El objetivo de este reporte es mostrar la importancia del uso de dispositivos (específicamente videolaringoscopio) en pacientes con predicción de vía aérea difícil. Presentación del caso. Hombre de 63 años con gran masa facial con extensión a nariz, labio superior, erosión a nivel del maxilar superior que ocupaba cavidad oral, con predictores de ventilación e intubación difícil, programado para rinectomía, osteotomía Lefort II, reconstrucción y traqueostomía, con intubación exitosa con videolaringoscopio en primer intento bajo sedación consciente y ventilación espontánea. Discusión. La vía aérea difícil es un escenario relacionado a factores externos e internos del paciente y a complicaciones pre e intraoperatorias. El videolaringoscopio es una herramienta útil que permite la intubación exitosa y disminuye los posibles eventos adversos (como se observó en el paciente del caso presentado) y es descrito en diferentes reportes de casos con compromiso parcial o total de la vía aérea. Conclusión. La videolaringoscopia, en casos de vía aérea difícil anticipada, está asociada con un menor tiempo de intubación, un buen perfil de seguridad y una alta tasa de éxito, comparable a la del fibrobroncoscopio, se logra la intubación en el primer intento en la mayoría de las veces y, por ello, debería considerarse como primera opción.


Introduction. Management of an anticipated difficult airway is an anesthetic challenge that involves preoperative assessment of the patient's specific anatomic characteristics and risk factors. Difficult intubation occurs in 1.6 of 1,000 events and failed intubation in 0.06 of 1,000 events. The objective of this report is to show the importance of the use of devices (specifically videolaryngoscope) in patients with predicted difficult airway. Case Presentation. 63-year-old man with large facial mass with extensión to the nose, upper lip, erosion at the level of the upper jaw occupying the oral cavity, with predictors of ventilation and difficult intubation, scheduled for rhinectomy, Lefort II osteotomy, reconstruction and tracheostomy, with successful intubation with videolaryngoscope on the first attempt under conscious sedation and spontaneous ventilation. Discussion. Difficult airway is a scenario related to external and internal patient factors and to pre- and intraoperative complications. The videolaryngoscope is a useful tool that allows successful intubation and decreases possible adverse events (as observed in the patient of the case presented) and is described in different reports of cases with partial or total airway compromise. Conclusion. Videolaryngoscopy, in cases of anticipated difficult airway, is associated with a shorter intubation time, a good safety profile and a high success rate, comparable to that of fibrobronchoscopy, intubation is achieved on the first attempt in most cases and should therefore be considered as a first choice.


Introdução. O manejo da via aérea difícil antecipada é um desafio anestésico que envolve a avaliação pré-operatória das características anatômicas e dos fatores de risco específicos do paciente. A intubação difícil ocorre em 1.6 de 1,000 eventos e a intubação falha em 0.06 de 1,000 eventos. O objetivo deste relato é mostrar a importância do uso de dispositivos (especificamente videolaringoscópio) em pacientes com previsão de via aérea difícil. Apresentação do caso. Homem de 63 anos com grande massa facial estendendo-se ao nariz, lábio superior e erosão ao nível do maxilar superior que ocupava a cavidade oral, com preditores de ventilação e intubação difícil, programado para rinectomia, osteotomia Lefort II, reconstrução e traqueostomia, com intubação bem-sucedida, com videolaringoscópio na primeira tentativa sob sedação consciente e ventilação espontânea. Discussão. A via aérea difícil é um cenário relacionado a fatores externos e internos do paciente e a complicações pré e intraoperatórias. O videolaringoscópio é uma ferramenta útil que permite o sucesso da intubação e reduz possíveis eventos adversos (como observado no paciente do caso apresentado) e está descrito em diversos relatos de casos com comprometimento parcial ou total da via aérea. Conclusão. A videolaringoscopia, em casos de via aérea difícil antecipada, está associada a um menor tempo de intubação, um bom perfil de segurança e uma alta taxa de sucesso, comparável à fibrobroncoscopia, a intubação é realizada na primeira tentativa na maioria dos casos e, portanto, deve ser considerada como a primeira opção.


Subject(s)
Airway Management , Laryngoscopy , Carcinoma, Squamous Cell , Intubation , Anesthesia
4.
Fisioter. Pesqui. (Online) ; 29(4): 380-385, Oct.-Dec. 2022. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1421491

ABSTRACT

RESUMO A pressão do cuff (Pcuff) ideal deve ser capaz de prevenir a microaspiração de secreções orofaríngeas por escapes aéreos e evitar lesão da mucosa traqueal. Normalmente, realiza-se a monitorização por meio de manômetro, buscando manter a Pcuff entre 20 e 30cmH2O. O método do volume mínimo de oclusão (VMO) consiste em insuflar minimamente o balonete, utilizando uma seringa, para que não ocorram vazamentos. O objetivo deste estudo foi avaliar a capacidade do método do VMO de individualizar o ajuste da Pcuff em pacientes ventilados mecanicamente. Trata-se de um estudo transversal, prospectivo, com 25 pacientes adultos, com tempo de ventilação mecânica (VM) superior a 48 horas. A Pcuff foi medida em dois momentos: inicial e por VMO. A prevalência de Pcuff fora dos limites de normalidade foi de 76%. Ocorreu vazamento na medida inicial em nove pacientes, sendo que, para quatro, a medida estava dentro dos valores de referência. Os outros cinco apresentaram Pcuff<20cmH2O. No ajuste pelo método VMO, todos os pacientes apresentaram Pcuff no limite de normalidade. Os pacientes sem vazamento com Pcuff>30cmH2O tiveram redução quando ajustados pelo VMO (45,4±9,6 vs 28,5±1,6cmH2O; p<0,001). Podemos concluir que o método do VMO foi capaz de individualizar a Pcuff dentro dos valores de referência em todos os pacientes.


RESUMEN La presión del manguito (Pmanguito) ideal debería ser capaz de prevenir la microaspiración de secreciones orofaríngeas por el escape de aire y evitar daños en la mucosa traqueal. En general, la monitorización se da a través de un manómetro al buscar mantener la Pmanguito entre 20 y 30 cmH2O. La técnica de volumen de oclusión mínimo (VOM) consiste en inflar al mínimo el manguito, utilizando una jeringa, para que no escape el aire. El objetivo de este estudio fue evaluar la capacidad de la técnica de VOM para individualizar el ajuste de la Pmanguito en pacientes con ventilación mecánica. Se trata de un estudio transversal, prospectivo, realizado con 25 pacientes adultos, con tiempo de ventilación mecánica (VM) superior a 48 horas. La Pmanguito se dio en dos momentos: inicial y por VMO. La prevalencia de la Pmanguito fuera de los límites normales fue del 76%. Se detectó el escape de aire en la medida inicial de nueve pacientes, entre los cuales cuatro tuvieron una medición dentro de los valores de referencia. Los otros cinco tenían una Pmanguito<20cmH2O. En el ajuste por la técnica de VMO, todos los pacientes tuvieron Pmanguito al límite de los valores normales. Los pacientes que no habían presentado escape de aire con Pmanguito>30cmH2O tuvieron una reducción cuando hubo un ajuste del VMO (45,4±9,6 vs 28,5±1,6cmH2O; p<0,001). Se concluye que la técnica de VMO fue capaz de individualizar la Pmanguito dentro de los valores de referencia en todos los pacientes.


ABSTRACT The ideal cuff pressure (Pcuff) must prevent microaspiration of oropharyngeal secretions due to air leakage and avoid injury to the tracheal mucosa. Usually, monitoring consists of a manometer to keep the Pcuff between 20 and 30cmH2O. The minimal occlusive volume (MOV) method minimally inflates the cuff using a syringe so that no leakage occurs. This study aims to evaluate the ability of the minimal occlusive method to individualize the Pcuff adjustment in mechanically ventilated patients. Cross-sectional prospective study with 25 adult patients with more than 48 hours of mechanical ventilation. Cuff pressure was measured at two moments: initial and by MOV. The prevalence of Pcuff outside the normal range was 76%. Leakage in the initial measurement occurred in 9 patients, 4 of whom were within the reference values. The other 5 patients presented Pcuff<20cmH2O. In the adjustment by the MOV method, all patients presented Pcuff at the limit of normality. Patients without leakage with Pcuff>30cmH2O had a reduction when adjusted for MOV (45.4±9.6 against 28.5±1.6cmH2O; p<0.001). We can conclude that the minimal occlusive volume method was able to individualize the Pcuff within the reference values in all patients.

5.
Rev. latinoam. enferm. (Online) ; 29: e3434, 2021. tab
Article in English | BDENF, LILACS | ID: biblio-1280484

ABSTRACT

Objective: construction and validation in appearance and content of the competence frameworks and of the Entrustable Professional Activities to develop skills in the training of nurses to assist the airway of adult patients in urgency and emergency situations. Method: a descriptive and methodological study developed in four phases: in the first, a workshop was held, composed of experts, for the construction of the competence frameworks; in the second, the material was validated using the Snowball Technique and the Delphi Technique, in the third, content analysis and calculation of the Content Validation Index were conducted; and in the fourth phase, the Entrustable Professional Activities were built, validated in simulated workshops. Results: the competence frameworks were built and validated, with a resulting CVI≥0.85 in all the items. The Entrustable Professional Activities were validated by experts regarding their applicability; of these, 44% stated they were applicable in simulated environments, 100% that they were useful content and with appropriate language, 22% suggested the insertion of new items to assess competence, 11% reported the difficulty of assessing competence individually in the clinical settings, and 11% of the experts referred to the need for prior training of the teacher/facilitator to use it. Conclusion: the study resulted in the construction of competence frameworks and six Entrustable Professional Activities relating them to the domains of essential competences in the training of nurses to assist the airway of adult patients in urgency and emergency situations. The participation of experts in the construction and validation of this material was essential to guarantee the theoretical and practical relevance of the result.


Objetivo: construção e validação em aparência e conteúdo dos marcos de competências e das Entrustable Professional Activities para desenvolver as competências na formação do enfermeiro para a assistência à via aérea de pacientes adultos em urgência e emergência. Método: estudo descritivo, metodológico desenvolvido em quatro fases: na primeira realizou-se uma oficina, composta por experts, para a construção dos marcos de competências; na segunda houve a validação dos material através da Snowball Technique e Técnica Delphi, na terceira ocorreu a análise de conteúdo e cálculo do Índice de Validação de Conteúdo; e na quarta fase foram construídas as Entrustable Professional Activities, validadas em oficinas simuladas. Resultados: construídos e validados os marcos de competências resultando em todos os itens IVC≥0,85. As Entrustable Professional Activities foram validadas por experts quanto à sua aplicabilidade, destes 44% referiram serem aplicáveis em ambientes simulados, 100% refeririam ser um conteúdo útil e com linguagem adequada, 22% sugeriram a inserção de novos itens para avaliar a competência, 11% relataram a dificuldade de avaliar a competência individualmente nos cenários clínicos, 11% experts referiram a necessidade de capacitação prévia do docente/facilitador para a utilização. Conclusão: o estudo resultou na construção dos marcos de competências e seis Entrustable Professional Activities relacionando-os com os domínios de competências essenciais na formação do enfermeiro para a assistência à via aérea de pacientes adultos em urgência e emergência. A participação dos experts na construção e na validação desse material foi fundamental para garantir a relevância teórica e prática do resultado.


Objetivo: construcción y validación de la apariencia y el contenido de los marcos de competencias y de las Entrustable Professional Activities para desarrollar las competencias en la formación de enfermeros para asistir la vía aérea de pacientes adultos en urgencia y emergencia. Método: estudio descriptivo, metodológico desarrollado en cuatro fases: en la primera se realizó un taller, integrado por experts, para la construcción de marcos de competencias; en el segundo se realizó la validación de los materiales a través de la Snowball Technique y la Técnica Delphi, en el tercero se realizó el análisis de contenido y cálculo del Índice de Validación de Contenido; y en la cuarta fase se construyeron Entrustable Professional Activities, validadas en talleres simulados. Resultados: se construyeron y validaron marcos de competencias, resultando en todos los ítems IVC≥0,85. Las Entrustable Professional Activities fueron validadas por experts en cuanto a su aplicabilidad, de estos el 44% dijo que eran aplicables en entornos simulados, el 100% dijo que eran contenidos útiles y con lenguaje adecuado, el 22% sugirió la inserción de nuevos ítems para evaluar competencia, el 11% reportó dificultad para evaluar la competencia individualmente en entornos clínicos, el 11% de los experts reportó la necesidad de capacitación previa del docente/facilitador para utilizarla. Conclusión: el estudio resultó en la construcción de marcos de competencias y seis Entrustable Professional Activities relacionándolos con los dominios de competencias esenciales en la formación de enfermeros para asistir la vía aérea de pacientes adultos en urgencia y emergencia. La participación de experts en la construcción y validación de este material fue fundamental para asegurar la relevancia teórica y práctica del resultado.


Subject(s)
Humans , Male , Female , Adult , Delphi Technique , Clinical Competence , Emergency Nursing , Education, Nursing , Airway Management , Nurses , Nursing Assessment
6.
Rev. bras. anestesiol ; 70(5): 553-555, Sept.-Oct. 2020. graf
Article in English, Portuguese | LILACS | ID: biblio-1143970

ABSTRACT

Abstract Hydatid cyst in the cervical region is an extremely rare condition that can create challenges for anesthesiologists. Timely recognition of difficult airway and preparing the management plan is crucial to avoid life-threatening complications such as hypoxic brain damage. We describe a case of difficult airway management in a patient with massive cervical hydatid cyst. We used a low-dose ketamine-propofol sedation and lidocaine spray for local oropharyngeal anesthesia. Muscular relaxants were not used, and spontaneous breathing was maintained during intubation. Recognition, assessment, and perioperative planning are essential for difficult airway management in patients with cervical hydatid cyst.


Resumo O cisto hidático na região cervical é uma condição extremamente rara que pode criar desafios para os anestesiologistas. O reconhecimento oportuno das vias aéreas difíceis e a preparação do plano de manejo são cruciais para evitar complicações com risco de vida, como danos cerebrais hipóxicos. Descrevemos um caso de difícil controle das vias aéreas em um paciente com cisto hidático cervical maciço. Utilizamos sedação com cetamina-propofol em baixa dose e spray de lidocaína para anestesia local orofaríngea. Relaxantes musculares não foram utilizados e a respiração espontânea foi mantida durante a intubação. O reconhecimento, a avaliação e o planejamento perioperatório são essenciais para o manejo difícil das vias aéreas em pacientes com cisto hidático cervical.


Subject(s)
Humans , Male , Adult , Airway Obstruction/parasitology , Echinococcosis/complications , Cervical Cord/parasitology , Propofol/administration & dosage , Echinococcosis/surgery , Airway Management , Intubation, Intratracheal , Ketamine/administration & dosage , Anesthesia, Local/adverse effects , Lidocaine/administration & dosage
7.
Rev. bras. ter. intensiva ; 32(3): 433-438, jul.-set. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1138510

ABSTRACT

RESUMO Objetivo: Descrever o uso do bloqueio neuromuscular e de outras práticas entre os médicos brasileiros atuantes em unidades de terapia intensiva para pacientes adultos. Métodos: Um levantamento nacional on-line foi aplicado a intensivistas brasileiros. As questões foram selecionadas utilizando o método Delphi e avaliavam os dados demográficos dos médicos, as características da unidade de terapia intensiva, as práticas relativas ao manuseio das vias aéreas e o uso de bloqueio neuromuscular e sedação durante a intubação endotraqueal na unidade de terapia intensiva. Como desfecho secundário, aplicamos uma análise multivariada para avaliar fatores associados com o uso do bloqueio neuromuscular. Resultados: Responderam ao questionário 565 intensivistas de todas as regiões do país. A maioria dos que responderam era homens (65%), com média de idade de 38 ± 8,4 anos, e 58,5% dos participantes tinham título de especialista em terapia intensiva. Apenas 40,7% dos intensivistas relataram o uso de bloqueio neuromuscular durante todas ou em mais de 75% das intubações endotraqueais. Na análise multivariada, o número de intubações realizadas por mês e a especialização do médico em anestesiologia se associaram diretamente com o uso frequente de bloqueio neuromuscular. Etomidato e cetamina foram utilizados mais comumente na situação clínica de hipotensão e choque, enquanto propofol e midazolam foram mais comumente prescritos em situações de estabilidade hemodinâmica. Conclusão: O relato de uso de bloqueio neuromuscular foi baixo entre intensivistas, e os fármacos sedativos foram escolhidos segundo a estabilidade hemodinâmica do paciente. Estes resultados podem ajudar no delineamento de futuros estudos relativos ao manuseio das vias aéreas no Brasil.


Abstract Objective: To describe the use of neuromuscular blockade as well as other practices among Brazilian physicians in adult intensive care units. Methods: An online national survey was designed and administered to Brazilian intensivists. Questions were selected using the Delphi method and assessed physicians' demographic data, intensive care unit characteristics, practices regarding airway management, use of neuromuscular blockade and sedation during endotracheal intubation in the intensive care unit. As a secondary outcome, we applied a multivariate analysis to evaluate factors associated with the use of neuromuscular blockade. Results: Five hundred sixty-five intensivists from all Brazilian regions responded to the questionnaire. The majority of respondents were male (65%), with a mean age of 38 ( 8.4 years, and 58.5% had a board certification in critical care. Only 40.7% of the intensivists reported the use of neuromuscular blockade during all or in more than 75% of endotracheal intubations. In the multivariate analysis, the number of intubations performed monthly and physician specialization in anesthesiology were directly associated with frequent use of neuromuscular blockade. Etomidate and ketamine were more commonly used in the clinical situation of hypotension and shock, while propofol and midazolam were more commonly prescribed in the situation of clinical stability. Conclusion: The reported use of neuromuscular blockade was low among intensivists, and sedative drugs were chosen in accordance with patient hemodynamic stability. These results may help the design of future studies regarding airway management in Brazil.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Neuromuscular Blockade/methods , Airway Management/methods , Hypnotics and Sedatives/administration & dosage , Intubation, Intratracheal/methods , Brazil , Surveys and Questionnaires , Critical Care/methods , Intensive Care Units
8.
Rev. latinoam. enferm. (Online) ; 28: e3347, 2020. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1126960

ABSTRACT

Objective: to compare the mean development time of the techniques of direct laryngoscopy and insertion of supraglottic devices; and to evaluate the success rate in the first attempt of these techniques, considering health professionals wearing specific personal protective equipment (waterproof overalls; gloves; boots; eye protection; mask). Method: meta-analysis with studies from LILACS, MEDLINE, CINAHL, Cochrane, Scopus and Web of Science. The keywords were the following: personal protective equipment; airway management; intubation; laryngeal masks. Results: in the "reduction of the time of the procedures" outcome, the general analysis of the supraglottic devices in comparison with the orotracheal tube initially presented high heterogeneity of the data (I2= 97%). Subgroup analysis had an impact on reducing heterogeneity among the data. The "laryngeal mask as a guide for orotracheal intubation" subgroup showed moderate heterogeneity (I2= 74%). The "2ndgeneration supraglottic devices" subgroup showed homogeneity (I2= 0%). All the meta-analyses favored supraglottic devices. In the "success in the first attempt" outcome, moderate homogeneity was found (I2= 52%), showing a higher proportion of correct answers for supraglottic devices. Conclusion: in the context of chemical, biological or radiological disaster, the insertion of the supraglottic device proved to be faster and more likely to be successful by health professionals. PROSPERO record (CRD42019136139).


Objetivo: comparar o tempo médio do desenvolvimento das técnicas de laringoscopia direta e de inserção de dispositivos supraglóticos e avaliar a taxa de sucesso na primeira tentativa dessas técnicas, considerando a utilização de equipamentos de proteção individual específicos (macacão impermeável; luvas; botas; proteção ocular; máscara) pelos profissionais de saúde. Método: metanálise com estudos das bases LILACS, MEDLINE, CINAHL, Cochrane, Scopus e Web of Science. As palavras-chave foram: personal protective equipment; airway management; intubation; laryngeal masks. Resultados: no desfecho redução "do tempo dos procedimentos" a análise geral dos dispositivos supraglóticos em comparação com o tubo orotraqueal apresentou inicialmente alta heterogeneidade dos dados (I2 = 97%). A análise por subgrupos impactou na redução da heterogeneidade entre os dados. O subgrupo "máscara laríngea como guia para intubação orotraqueal" demonstrou heterogeneidade moderada (I2 = 74%). O subgrupo "dispositivos supraglóticos de 2ª geração" evidenciou homogeneidade (I2 = 0%). Todas as metanálises foram favoráveis aos dispositivos supraglóticos. No desfecho "êxito na primeira tentativa" foi encontrada homogeneidade moderada (I2 = 52%), demonstrando maior proporção de acerto para dispositivos supraglóticos. Conclusão: no contexto do desastre químico, biológico ou radiológico, a inserção do dispositivo supraglótico revelou ser mais rápida e apresentar maior chance de acerto por profissionais de saúde. Registro PROSPERO (CRD42019136139).


Objetivo: comparar el tiempo medio de desarrollo de las técnicas de laringoscopia directa y de inserción de dispositivos supraglóticos y evaluar la tasa de éxito obtenida en el primer intento de dichas técnicas con profesionales sanitarios provistos de equipos de protección individual específicos (mono impermeable, guantes, botas, protección ocular, mascarilla). Método: meta-análisis con estudio de las bases de datos LILACS, MEDLINE, CINAHL, Cochrane, Scopus y Web of Science. Las palabras clave fueron las siguientes: personal protective equipment; airway management; intubation; laryngeal masks. Resultados: en el resultado "reducción del tiempo de los procedimientos", el análisis general de los dispositivos supraglóticos en comparación con el tubo orotraqueal presentó, inicialmente, una alta heterogeneidad de los datos (I2= 97%). El análisis por subgrupos dio como resultado una reducción de la heterogeneidad entre los datos. El subgrupo "mascarilla laríngea como guía para la intubación orotraqueal" mostró una heterogeneidad moderada (I2= 74%). El subgrupo "dispositivos supraglóticos de 2ª generación" mostró homogeneidad (I2= 0%). Todos los meta-análisis fueron favorables a los dispositivos supraglóticos. En el resultado "éxito en el primer intento" se halló una homogeneidad moderada (I2= 52%), obteniendo una mayor proporción de aciertos con el uso de dispositivos supraglóticos. Conclusión: en el contexto de un desastre químico, biológico o radiológico, se ha demostrado que la inserción del dispositivo supraglótico es más rápida y que los profesionales sanitarios obtienen una mayor probabilidad de acierto. Registro PROSPERO (CRD42019136139).


Subject(s)
Protective Devices , Bathroom Equipment , Incidence , Laryngeal Masks , Meta-Analysis , Disasters , Airway Management , Personal Protective Equipment , Equipment and Supplies Utilization , Intubation , Laryngoscopy
9.
Rev. Col. Bras. Cir ; 47: e20202510, 2020. tab, graf
Article in English | LILACS | ID: biblio-1136560

ABSTRACT

ABSTRACT Introduction: percutaneous dilatational tracheostomy is currently one of the main procedures performed in an intensive care unit (ICU). However, there are no well-defined indicators of technical difficulty in performing the procedure. Objectives: to define predictors of difficulty in performing bedside percutaneous dilatational tracheostomy. Methodology: prospective cohort study encompassing 21 patients who underwent bedside percutaneous dilatational tracheostomy in the ICU at a single center. Results: Sternohyoid (SH) distance shorter than 7 cm is associated with a 50% increase in the risk of technical difficulty (OR 0.44 and p <0.03). Conclusion: the reduction in (SH) distance is related to an increased risk of difficulty in performing percutaneous dilatational tracheostomy in the ICU bed.


RESUMO Introdução: a traqueostomia percutânea é hoje um dos principais procedimentos realizados em unidade de terapia intensiva (UTI). Não há, contudo, indicadores bem definidos de dificuldade técnica na realização do procedimento. Objetivos: definir preditores de dificuldade para realização de traqueostomia percutânea. Metodologia: estudo de coorte prospectivo no qual foram incluídos 21 pacientes submetidos a traqueostomia percutânea à beira leito, na UTI, em um único centro. Resultados: distância EH menor que 7 cm está associada a aumento de 50% na chance de dificuldade técnica (OR 0,44 e p<0,03). Conclusão: a redução da distância EH está relacionada com aumento do risco de dificuldade em realizar a traqueostomia percutânea à beira do leito, em UTI.


Subject(s)
Humans , Respiratory Insufficiency/therapy , Tracheostomy/methods , Respiratory Insufficiency/etiology , Tracheostomy/adverse effects , Pilot Projects , Prospective Studies , Dilatation/adverse effects , Dilatation/methods , Intensive Care Units
10.
Rev. Col. Bras. Cir ; 47: e20202522, 2020. tab, graf
Article in English | LILACS | ID: biblio-1136568

ABSTRACT

ABSTRACT Objective: to compare the acquisition and retention of knowledge about surgical cricothyroidostomy by the rapid four-step technique (RFST), when taught by expository lecture, low fidelity and high-fidelity simulation models. Methods: ninety medical students at UFPR in the first years of training were randomized assigned into 3 groups, submitted to different teaching methods: 1) expository lectures, 2) low-fidelity simulator model, developed by the research team or 3) high-fidelity simulator model (commercial). The procedure chosen was surgical cricothyroidostomy using the RFST. Soon after lectures, the groups were submitted to a multiple-choice test with 20 questions (P1). Four months later, they underwent another test (P2) with similar content. Analysis of Variance was used to compare the grades of each group in P1 with their grades in P2, and the grades of the 3 groups 2 by 2 in P1 and P2. A multiple comparisons test (post-hoc) was used to check differences within each factor (test and group). Statistical significance was considered when p<0.05. Statistical analysis was performed in the statistical software R version 3.6.1. Results: each group was composed of 30 medical students, without demographic differences between them. The mean scores of the groups of the expositive lecture, of the simulator of low fidelity model and of high-fidelity simulator model in P1 were, respectively, 75.00, 76.09, and 68.79, (p<0.05). In P2 the grades were 69.84, 75.32, 69.46, respectively, (p>0.05). Conclusions: the simulation of low fidelity model was more effective in learning and knowledge retention, being feasible for RFST cricothyroidostomy training in inexperienced students.


RESUMO Objetivo: comparar a aquisição e retenção de conhecimento, sobre cricotireoidostomia cirúrgica pela técnica rápida de quatro tempos (TRQT), quando ensinada por aula expositiva, simulação de baixa fidelidade e de alta fidelidade. Métodos: noventa alunos de medicina da UFPR dos primeiros anos foram randomizados em 3 grupos: 1) aula expositiva, 2) simulador de baixa fidelidade, ou 3) simulador de alta fidelidade (comercial). O tema exposto foi a cricotireoidostomia cirúrgica pela técnica rápida de quatro tempos (TRQT). Logo após as aulas, os grupos foram submetidos a uma prova de múltipla escolha com 20 questões (P1). Quatro meses após, realizaram uma outra prova (P2), com conteúdo similar. Análise de Variância foi usada para comparar as notas de cada grupo na P1 com suas notas na P2, e as notas dos 3 grupos de 2 a 2 na P1 e na P2. Utilizou-se um teste de comparações múltiplas (post-hoc) para verificar diferenças dentro de cada fator (prova e grupo). Considerou-se significância estatística quando p<0,05. A análise estatística foi feita no software estatístico R versão 3.6.1. Resultados: cada grupo foi composto de 30 estudantes de medicina, sem diferenças demográficas entre os grupos. As notas médias dos grupos da aula expositiva, do modelo de baixa fidelidade e de alta fidelidade na P1 foram, respectivamente, 75,00, 76,09, e 68,79, (p<0,05). Na P2 as notas foram respectivamente 69,84, 75,32, 69,46, (p>0,05). Conclusão: a simulação de baixa fidelidade foi mais eficaz no aprendizado e na retenção de conhecimento, sendo viável para o treinamento de cricotireoidostomia TRQT em alunos inexperientes.


Subject(s)
Humans , Cricoid Cartilage/surgery , Educational Measurement , Airway Management , Simulation Training/methods , Students, Medical , Prospective Studies , Clinical Competence , Learning
11.
Fisioter. Pesqui. (Online) ; 26(4): 427-432, out.-dez. 2019. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1056204

ABSTRACT

ABSTRACT Several respiratory diseases are characterized by hypersecretion, requiring airway clearance therapy (ACT). Oral high-frequency oscillation (OHFO) devices are effective to enable daily ACT; however, they are still too expensive to become available for low-income patients. We sought to develop a low-cost device (OHFO-LC) and compare its physical properties with those OHFO commercially available (Shaker and Flutter). The OHFO-LC was developed from polyvinyl chloride material and one stainless steel sphere. Pressures and frequencies were measured at flows of 4, 6, 8, 10 and 15L/min. Pressures at the mouthpieces were measured by a transducer connected to a microcomputer. The oscillation frequencies were obtained from the graph of the pressure. The frequencies and pressures were compared among groups using one-way Anova and Tukey's post hoc tests, p≤0.05. There were no differences among the frequencies of the three devices in all tested flows. The OHFO-LC device showed a higher positive expiratory pressure compared with the Shaker at all tested flows (4 L/min: 4.7±1.2 vs. 1.0±0.2 cmH2O; 6 L/min: 8.6±1.5 vs. 3.5±0.5 cmH2O; 8 L/min: 10.8±1.6 vs. 5.4±0.2 cmH2O; 10 L/min: 13.5±1.2 vs. 7.7±0.4 cmH2O; 15 L/min: 14.3±1.1 vs. 7.8±0.2 cmH2O; OHFO-LC vs. Shaker; p≤0.05) and at 10 and 15 L/min compared with Flutter (10 L/min: 13.5±1.2 vs. 7.5±1.2 cmH2O; 15 L/min: 14.3±1.1 vs. 8.2±1.2 cmH2O; OHFO-LC vs. Flutter, p≤0.05). The cost of the OHFO-LC device was much lower than both the Shaker and the Flutter. Our results showed that the OHFO-LC had physical properties with similar frequencies but higher pressures than other OHFO devices that are commercially available. Future studies are necessary to evaluate its clinical efficacy.


RESUMO Diversas doenças respiratórias são caracterizadas por hipersecreção com necessidade de higiene brônquica (HB). Osciladores orais de alta frequência (OOAF) são dispositivos que promovem HB diária; entretanto, seu custo pode ser inviável para aquisição por pacientes com baixa renda. Os objetivos deste estudo foram: desenvolver um OOAF de baixo custo (OOAF-BC) e comparar suas propriedades físicas com as dos disponíveis comercialmente (Shaker e Flutter). O OOAF-BC foi desenvolvido com material de polivinil clorido e uma esfera de aço inoxidável. As pressões e frequências foram mensuradas nos fluxos de 4, 6, 8, 10 e 15 L/min. As pressões nos bocais foram medidas por um transdutor conectado ao computador. As frequências de oscilação foram derivadas do gráfico de pressão. A comparação dos dispositivos foi feita por Anova com post hoc de Tukey, p≤0.05. Não houve diferença entre as frequências dos três dispositivos em todos os fluxos testados. O OOAF-BC apresentou pressão mais alta comparado ao Shaker em todos os fluxos testados (4 L/min: 4,7±1,2 vs. 1,0±0,2 cmH2O; 6 L/min: 8,6±1,5 vs. 3,5±0,5 cmH2O; 8 L/min: 10,8±1,6 vs. 5,4±0.2 cmH2O; 10 L/min: 13,5±1,2 vs. 7,7±0.4 cmH2O; 15 L/min: 14,3±1,1 vs. 7,8±0,2 cmH2O; OOAF-BC vs. Shaker; p≤0.05) e nos fluxos de 10 e 15 L/min comparado ao Flutter (10 L/min: 13,5±1,2 vs. 7,5±1,2 cmH2O; 15 L/min: 14,3±1,1 vs. 8,2±1,2 cmH2O; OOAF-BC vs. Flutter, p≤0.05). O custo do OOAF-BC foi pelo menos seis vezes menor. O OOAF-BC apresentou frequências similares e pressões mais altas que os outros OOAF comercialmente disponíveis. Estudos futuros são necessários para avaliar sua eficácia clínica.


RESUMEN Varias enfermedades respiratorias se caracterizan por hipersecreción, que requiere higiene bronquial (HB). Los osciladores orales de alta frecuencia (OOAF) son dispositivos que promueven la HB diaria; sin embargo, su costo puede no ser factible para la adquisición por parte de pacientes con bajos ingresos. Los objetivos de este estudio fueron desarrollar un OOAF de bajo costo (OOAF-BC) y comparar sus propiedades físicas con las de los disponibles comercialmente (Shaker y Flutter). El OOAF-BC se desarrolló con material de polivinilo clorado y una bola de acero inoxidable. Las presiones y frecuencias se midieron en flujos de 4, 6, 8, 10 y 15 L/min. Las presiones de la boquilla se midieron mediante un transductor conectado a la computadora. Las frecuencias de oscilación se derivaron del gráfico de presión. Se compararon los dispositivos con la utilización de Anova con post hoc de Tukey, p≤0,05. No hubo diferencias entre las frecuencias de los tres dispositivos en todos los flujos probados. El OOAF-BC mostró una presión más alta en comparación con Shaker en todos los flujos probados (4 L/min: 4,7±1,2 vs. 1,0±0,2 cmH2O; 6 L/min: 8,6±1,5 vs. 3,5±0,5 cmH2O; 8 L/min: 10,8±1,6 vs. 5,4±0,2 cmH2O; 10 L/min: 13,5±1,2 vs. 7,7±0,4 cmH2O; 15 L/min: 14,3±1,1 vs. 7,8±0,2 cmH2O; OOAF-BC vs. Shaker; p≤0,05) y con flujos de 10 y 15 L/min en comparación con Flutter (10 L/min: 13,5±1,2 vs. 7,5±1,2 cmH2O; 15 L/min: 14,3±1,1 vs. 8,2±1,2 cmH2O; OOAF-BC vs. Flutter, p≤0,05). El costo de OOAF-BC fue al menos seis veces menor. El OOAF-BC mostró frecuencias similares y presiones más altas que otros OOAF disponibles comercialmente. Se necesitan estudios futuros para evaluar su eficacia clínica.

12.
Rev. Col. Bras. Cir ; 43(6): 493-499, Nov.-Dec. 2016. tab
Article in English | LILACS | ID: biblio-842629

ABSTRACT

ABSTRACT Being a fast and safe method in the hands of well trained professionals in both prehospital and intrahospital care, Cricothyrotomy has been broadly recommended as the initial surgical airway in the scenario "can't intubate, can't ventilate", and is particularly useful when the obstruction level is above or at the glottis. Its prolonged permanence, however, is an endless source of controversy. In this review we evaluate the complications of cricothyrotomy and the need of its routine conversion to tracheotomy through a search on PubMed, LILACS and SciELO electronic databases with no restriction to the year or language of the publication. In total, we identified 791 references, retrieved 20 full text articles, and included nine studies in our review. The incidence of short-term complications ranged from zero to 31.6%, and the long-term complications, from zero to 7.86%. Subglotic stenosis was the main long-term reported complication, even though it was quite infrequent, occurring only in 2.9 to 5%. The frequency of conversion to tracheostomy varied from zero to 100%. Although a small frequency of long-term complications was found for emergency cricothyrotomy, the studies' low level of evidence does not allow the recommendation of routine use of cricothyrotomy as a secure definitive airway.


RESUMO A cricotireoidostomia, por ser um método rápido e, em geral, realizado com sucesso em ambientes pré e intra-hospitalares por profissionais treinados, tem sido amplamente preconizada como a via aérea cirúrgica inicial diante da situação "impossível intubar, impossível ventilar" e é especificamente útil quando a obstrução das vias aéreas ocorre na glote ou em nível supraglótico. Seu uso prolongado é, contudo, controverso. Nesta revisão procuramos avaliar as complicações da cricotireoidostomia de emergência, bem como, a necessidade rotineira de sua posterior conversão para traqueostomia através de pesquisa de estudos publicados sobre cricotireoidostomia de emergência nas bases de dados PubMed, LILACS e SciELO, sem restrição quanto ao ano de publicação. Assim foram identificados 791 estudos, dos quais 20 foram selecionados para leitura do texto integral, e, destes, nove foram incluídos nesta revisão. A taxa de complicações em curto prazo variou de zero a 31,6%, e a de complicações em longo prazo variou de zero a 7,86%. A estenose subglótica foi a principal complicação em longo prazo, relatada em 2,9 a 5% dos procedimentos. A taxa de conversão para traqueostomia variou de zero a 100%. Apesar da incidência reduzida de complicações em longo prazo o baixo nível de evidência dos estudos revisados não permite recomendar a cricotireoidostomia como uma via aérea definitiva segura.


Subject(s)
Humans , Tracheotomy , Tracheostomy , Cricoid Cartilage/surgery , Intubation, Intratracheal , Emergency Medical Services
13.
Rev. bras. anestesiol ; 66(2): 204-207, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-777412

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: The incidence of difficult airway reaches 10% of emergency intubations. Although few studies address the use of handmade introducer guides in emergency and intensive care environment, there are descriptions of handmade guides available on the Internet. We describe a case series on the use of a handmade introducer guide (bougie) for emergency intubation in patients with difficult airway. CASE REPORT: The handmade introducer guide was used in five consecutive patients with difficult airways, and clinical instability and in the absence of another immediate method to obtain an airway. This technique provided successful intubation and there were no complications. CONCLUSIONS: The use of the handmade introducer guide can be a useful option for the management of difficult airways.


RESUMO JUSTIFICATIVA E OBJETIVOS: A incidência de via aérea difícil chega a 10% das intubações de emergência. Ainda que poucos estudos abordem o emprego de guia introdutor artesanal no ambiente de emergência e terapia intensiva, há descrições de guias produzidas de forma artesanal disponíveis na internet. Nosso objetivo é descrever uma série de casos sobre o uso de um guia introdutor (Bougie) artesanal para intubação de emergência em pacientes com Via Aérea Difícil. RELATO DE CASO: O guia introdutor artesanal foi utilizado em cinco pacientes consecutivos com via aérea difícil, instabilidade clínica e falta de outro método imediato para a obtenção de uma via aérea. Essa técnica proporcionou sucesso na intubação e não houve complicações. CONCLUSÕES: A utilização do guia introdutor artesanal pode ser uma opção útil para o manejo de via aérea difícil.


Subject(s)
Humans , Male , Female , Adolescent , Aged , Aged, 80 and over , Emergencies , Airway Management/methods , Intubation, Intratracheal/methods , Equipment Design , Airway Management/instrumentation , Intubation, Intratracheal/instrumentation
14.
Rev. bras. anestesiol ; 66(2): 219-221, Mar.-Apr. 2016.
Article in English | LILACS | ID: lil-777401

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: The I-gel supraglottic airway has a non-inflatable cuff made from a gel-like thermoplastic elastomer. The use of the I-gel during anesthesia for spontaneously breathing patients or intermittent positive pressure ventilation has been reported. But there are a few published reports about the use of the I-gel with pressure-controlled ventilation. CONTENTS AND CONCLUSIONS: In this case report we described the use of the I-gel supraglottic airway along 48 h in intensive care unit for the management of ventilation in a patient needed mechanic ventilation but in whom tracheal intubation could not be performed.


RESUMO JUSTIFICATIVA E OBJETIVOS: O dispositivo supraglótico I-gel para o manejo das vias aéreas tem um manguito não insuflável feito de um elastômero termoplástico semelhante ao gel. Há relato sobre o uso do I-gel em pacientes sob anestesia para a ventilação, espontânea ou com pressão positiva intermitente. Porém, há poucos relatos publicados sobre o uso do I-gel com ventilação controlada por pressão. CONTEÚDO E CONCLUSÕES: Descrevemos neste relato de caso o uso do dispositivo supraglótico I-gel durante 48 horas em unidade de terapia intensiva para o manejo das vias aéreas em paciente que precisou de ventilação mecânica, mas no qual a intubação traqueal não pôde ser feita.


Subject(s)
Humans , Female , Respiration, Artificial/methods , Airway Management/methods , Equipment Design , Airway Management/instrumentation , Intensive Care Units , Middle Aged
15.
Rev. bras. enferm ; 69(2): 368-374, mar.-abr. 2016. graf
Article in Portuguese | LILACS, BDENF | ID: lil-783859

ABSTRACT

RESUMO Objetivo: ensinar manejo da via aérea com máscara laríngea a estudantes de enfermagem mediante aula expositivo-dialogada acompanhada de atividade prática em laboratório ou exclusivamente aula simulada. Método: ensaio clínico randomizado controlado. População: bacharelandos oitavo semestre. Amostra: 17 estudantes randomizados em grupo intervenção (GI: aula simulada) ou controle (GC: aula expositivo-dialogada e atividade prática em laboratório). Elaborados e validados instrumentos: avaliação escrita, cenário de simulação, avaliação clínica objetiva estruturada (checklist). Coletou-se dados em workshop. Aplicaram-se teste escrito e avaliação clínica estruturada em cenário de simulação filmada e avaliada por três experts. Resultados: idade 24,4±4,2 anos. Acertos GC: pré-teste 66±10%; pós-teste 84±8%. GI: pré-teste 65±5%; pós-teste 86±11%. Cenário: GC 78±5.2%; GI 84±8.9%. Conclusão: estratégias proporcionaram aquisição de conhecimento, habilidades e tomada de decisão, indispensáveis para atingir objetivos do cenário. Houve incorporação de conhecimento em manejo da via aérea com máscara laríngea, evidenciado pelo incremento dos escores no teste escrito e cenário.


RESUMEN Objetivo: enseñar manejo de la vía aérea con máscara laríngea a estudiantes de enfermería mediante aula expositiva-dialogada acompañada de actividad práctica en laboratorio o exclusivamente aula simulada. Método: ensayo Clínico Randomizado Controlado. Población: universitarios del octavo semestre. Muestra: 17 estudiantes randomizados en grupo intervención (GI: aula simulada) o control (GC: aula expositivo-dialogada y actividad práctica en laboratorio). Instrumentos elaborados y validados: evaluación escrita, escenario de simulación, evaluación clínica objetiva estructurada (checklist). Datos colectados en workshop. Se aplicaron prueba escrita y evaluación clínica estructurada en escenario de simulación filmada y evaluada por tres experts. Resultados: edad 24.4±4.2 años. Aciertos GC: pre-teste 66±10%; pos-teste 84±8%. GI: pre-teste 65±5%; pos-teste 86±11%. Escenario: GC 78±5.2%; GI 84±8.9%. Conclusión: estrategias proporcionaron adquisición de conocimiento, habilidades y toma de decisión, indispensables para alcanzar objetivos del escenario. Hubo incorporación de conocimiento en manejo de la vía aérea con máscara laríngea, evidenciado por el incremento de los scores en el teste escrito y en el escenario.


ABSTRACT Objective: to teach airway management with laryngeal mask to nursing students through dialogic lectures along with laboratory activities or exclusively through simulation class. Method: randomized controlled trial. Population: eighth semester bachelor's degree students. Sample: 17 students randomized in the intervention group (IG: simulation class) or control group (CG: dialogic lecture along with laboratory activities). Elaborated and validated instruments: written test, simulation scenario, objective structured clinical examination (checklist). Data collected from workshop. Structured clinical examination in simulation scenario filmed and evaluated by 3 experts, and written tests were applied. Results: 24.4±4.2 years old. Right answers percentage: CG: pre-test 66±10%; post-test 84±8%. IG: pre-test 65±5%; post-test 86±11%. Scenario: CG 78±5.2%; IG 84±8.9%. Conclusion: strategies allowed the development of knowledge, skills and decision-making, which are essential to achieve the scenario objectives. Knowledge was incorporated in airway management with laryngeal mask, shown by the increase in the scenario and written tests scores.


Subject(s)
Humans , Female , Adult , Young Adult , Laryngeal Masks , Education, Nursing/methods , Airway Management
16.
Rev. Col. Bras. Cir ; 42(3): 193-196, May-June 2015. ilus
Article in English | LILACS | ID: lil-756002

ABSTRACT

OBJECTIVE: To evaluate the acceptability of an educational project using A porcine model of airway for teaching surgical cricothyroidotomy to medical students and medical residents at a university hospital in southern Brazil. METHODS: We developed a teaching project using a porcine model for training in surgical cricothyroidotomy. Medical students and residents received lectures about this surgical technique and then held practical training with the model. After the procedure, all participants filled out a form about the importance of training in airway handling and the model used. RESULTS: There were 63 participants. The overall quality of the porcine model was estimated at 8.8, while the anatomical correlation between the model and the human anatomy received a mean score of 8.5. The model was unanimously approved and considered useful in teaching the procedure. CONCLUSION: The training of surgical cricothyroidotomy with a porcine model showed good acceptance among medical students and residents of this institution.


OBJETIVO: Avaliar a aceitabilidade de um projeto de ensino utilizando modelo porcino de vias aéreas no ensino da cricotiroidotomia cirúrgica para estudantes de Medicina e médicos residentes em um hospital universitário no sul do Brasil. MÉTODOS: Foi desenvolvido um projeto de ensino usando modelo porcino para treinamento em cricotiroidotomia cirúrgica. Estudantes de Medicina e residentes receberam aula teórica sobre esta técnica cirúrgica e, em seguida, realizaram no modelo o treinamento prático. Após o procedimento, todos os participantes preencheram um formulário acerca da importância do treinamento em manuseio de vias aéreas e do modelo utilizado. RESULTADOS: Houve 63 participantes. A qualidade geral do modelo porcino foi estimada em 8,8, enquanto a correlação anatômica entre o modelo e a anatomia humana recebeu o escore médio de 8,5 entre os treinandos. O modelo foi unanimemente aprovado e considerado útil no ensino do procedimento. CONCLUSÃO: O treinamento de cricotiroidotomia cirúrgica em modelo porcino apresentou boa aceitação entre os estudantes de Medicina e os residentes desta Instituição.


Subject(s)
Humans , Airway Management , Cricoid Cartilage , Education , General Surgery , Teaching , Thyroid Cartilage
17.
Rev. bras. ter. intensiva ; 26(4): 367-372, Oct-Dec/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-732920

ABSTRACT

Objetivo: Testar a eficácia da técnica de alívio de pressão de cuff por meio de uma válvula em manter níveis de pressão de cuff dentro da normalidade in vitro (Fase 1) e em pacientes internados em unidade de terapia intensiva (Fase 2), bem como testar a reprodutibilidade da técnica utilizando diferentes seringas. Métodos: Na Fase 1, uma cânula orotraqueal foi inserida em um modelo de traqueia. Seringas de 10 e 20mL foram utilizadas para insuflar o cuff da cânula. O cuff foi insuflado lenta e progressivamente até que o êmbolo da seringa se deslocasse em direção contrária da aplicação. Após a pausa do êmbolo, as pressões do balonete foram registradas. Na Fase 2, a mesma manobra de insuflação do cuff foi realizada em 20 pacientes, utilizando-se seringas de 5, 10 e 20mL, e foi comparada com as medidas de um manômetro. O índice de correlação intraclasse e a análise de Bland-Altman foram realizados para verificar a reprodutibilidade e a concordância entre as seringas. Os dados foram expressos como mediana (intervalo interquartil). Resultados: A reprodutibilidade entre as seringas foi nula, com índice de correlação intraclasse variando entre -0,33 e 0,8 (p>0,05). As pressões geradas com as seringas foram superiores à pressão obtida com o manômetro padrão: seringa de 5mL teve 105cmH2O (82,5-120cmH2O); seringa de 10mL teve ...


Objective: To test the effectiveness of using a cuff pressure relief valve technique to maintain cuff pressure levels within the normal in vitro range (Phase 1) in patients admitted to the intensive care unit (Phase 2) and to test the reproducibility of the technique using different syringes. Methods: In Phase 1, a tracheal tube was inserted into a trachea model. Ten- and 20mL syringes were used to inflate the cuff through the tracheal tube. The cuff was slowly and steadily inflated until the syringe plunger would move in the opposite direction of the application. After the plunger stopped, the cuff pressures were recorded. In Phase 2, the same maneuvers for inflating the cuff were performed on 20 patients using 5, 10, and 20mL syringes and were compared with manometer measurements. The intraclass correlation coefficient and Bland-Altman analysis were employed to determine the reproducibility and agreement between syringes. Data were expressed as medians (interquartile range). Results: There was no reproducibility between syringes with an intraclass correlation coefficient ranging between -0.33 and 0.8 (p>0.05). The pressures generated with the syringes were higher than the pressures generated using a standard manometer: the 5mL syringe pressure was 105cmH2O (82.5-120cmH2O), the 10mL syringe pressure was 69cmH2O (47.5-111.3cmH2O), and the 20mL syringe pressure was 45cmH2O (35-59.5cmH2O). The Bland-Altman analysis confirmed the large bias and variability between the ...


Subject(s)
Humans , Intensive Care Units , Intubation, Intratracheal/methods , Syringes , Intubation, Intratracheal/instrumentation , Pressure , Reproducibility of Results
18.
Acta paul. enferm ; 27(4): 319-325, 08/2014. tab
Article in Portuguese | LILACS, BDENF | ID: lil-720765

ABSTRACT

Objetivo: Identificar a prevalência do diagnóstico de enfermagem de desobstrução ineficaz de vias aéreas, indicadores clínicos e espectro de manifestação em crianças com infecção respiratória aguda; determinar associação entre os indicadores e a probabilidade de identificação. Métodos: Estudo transversal que incluiu 192 crianças internadas. Foram realizadas entrevistas e avaliação pulmonar, e os dados foram encaminhados a diagnosticadores para inferência diagnóstica. Utilizaram-se pacotes estatísticos para análise dos dados. Resultados: 71,9% das crianças apresentaram o diagnóstico em estudo. Os indicadores clínicos foram: tosse ineficaz, ruídos adventícios respiratórios, quantidade excessiva de muco, dispneia, ortopneia, mudança no ritmo respiratório e mudança na frequência respiratória; manifestados pelo espectro moderado. Os indicadores dispneia, inquietação, ortopneia, quantidade excessiva de muco, ruídos adventícios respiratórios e tosse ineficaz apresentaram relação linear significativa. Conclusão: O diagnóstico de enfermagem apresentou alta prevalência e associação entre os indicadores e a probabilidade de identificação do diagnóstico de enfermagem foi estabelecida. .


Objective: To identify the prevalence of nursing diagnosis of ineffective airway clearance, clinical indicators, and spectrum of manifestation in children with acute respiratory infection; to determine the association between its indicators and the probability of identification. Methods: Cross-sectional study involving 192 hospitalized children. Interviews and pulmonary evaluations were performed, and the data were sent to diagnosticians for diagnostic inference. Statistical packages were used for data analysis. Results: 71.9% of the children presented the diagnosis under study. The clinical indicators were ineffective cough, respiratory rales, excessive amount of mucus, dyspnea, orthopnea, change in breathing rate, and change in respiratory frequency; manifested by the moderate spectrum. The indicators of dyspnea, restlessness, orthopnea, excessive amount of mucus, respiratory rales, and ineffective cough showed a significant linear relationship. Conclusion: The nursing diagnosis showed a high prevalence and association between indicators and the likelihood of identifying the nursing diagnosis was established. .

19.
Braz. j. otorhinolaryngol. (Impr.) ; 79(5): 564-568, Sep-Oct/2013. tab, graf
Article in Portuguese | LILACS | ID: lil-688622

ABSTRACT

A laringomalácia é a anomalia congênita da laringe mais frequente, sendo responsável por cerca de 60% a 75% dos casos de estridor congênito. Apesar de seu curso benigno e autolimitado, 10% dos casos necessitam de intervenção. Atualmente, as supraglotoplastias são consideradas o tratamento padrão da laringomalácia grave. OBJETIVO: Descrever a experiência adquirida pelos autores no tratamento cirúrgico dos pacientes com laringomalácia grave. Metodologia: Estudo retrospectivo. MÉTODO: Os prontuários de 11 casos consecutivos de laringomalácia grave, submetidos ao tratamento cirúrgico entre 2003 e 2012, foram analisados quanto à idade, gênero, sintomas, doenças associadas, técnica cirúrgica adotada, tempo de extubação, complicações cirúrgicas, tempo de internação e evolução clínica. RESULTADOS: Dos 11 casos de laringomalácia grave, seis pacientes (54,5%) foram operados com o uso do laser de CO2 e em cinco pacientes (45,5%) foram realizadas a técnica a frio. Apenas um paciente (9,1%) necessitou reabordagem cirúrgica. Não foram observados casos de complicações cirúrgicas. Todos os pacientes apresentaram melhora clínica importante. CONCLUSÃO: A supraglotoplastia mostrou-se um procedimento eficaz e seguro no tratamento da laringomalácia grave. .


Laryngomalacia is the most frequent congenital abnormality of the larynx, accounting for approximately 60-75% of congenital stridor cases. Despite its benign and self-limited aspects, 10% of cases require intervention. Currently, supraglottoplasty is considered the standard treatment of severe laryngomalacia. OBJECTIVE: To describe the experience of the authors in the surgical treatment of patients with severe laryngomalacia. Methodology: A retrospective study. METHOD: The medical records of 11 consecutive cases of severe laryngomalacia who underwent surgical treatment between 2003 and 2012 were analyzed for age, gender, symptoms, associated diseases, surgical technique employed, extubation time, surgical complications, length of hospital stay and clinical outcome. RESULTS: Of the 11 cases of severe laryngomalacia, six patients (54.5%) were operated with the use of CO2 laser and five patients (45.5%) were submitted to the cold technique. Only 1 patient (9.1%) required surgical reintervention. There were no cases of surgical complications. All patients had clinical improvement. CONCLUSION: Supraglottoplasty proved to be effective and safe in the treatment of severe laryngomalacia. .


Subject(s)
Female , Humans , Infant , Male , Laryngomalacia/surgery , Retrospective Studies , Severity of Illness Index , Treatment Outcome
20.
Rev. bras. anestesiol ; 63(4): 359-362, jul.-ago. 2013. tab
Article in Portuguese | LILACS | ID: lil-680146

ABSTRACT

JUSTIFICATIVA E OBJETIVO: Descrever um protocolo de intubação com broncoscópio flexível (FBI, de flexible bronchoscopy intubation) em pacientes com via aérea difícil, sua eficácia e segurança. MÉTODOS: Foram revisados os prontuários médicos de pacientes diagnosticados com via aérea difícil que foram submetidos à broncoscopia flexível para intubação sob ventilação espontânea e sedação com midazolam e fentanil, de março de 2009 a dezembro de 2010. RESULTADOS: Foram selecionados 102 pacientes, 69 (67,7%) homens e 33 (32,3%) mulheres, com idade média de 44 anos. Em 59 pacientes com via aérea difícil prevista (57,8%) a FBI foi feita em centro cirúrgico; 39 (38,2%) ocorreram na Unidade de Terapia Intensiva e quatro casos (3,9%) na sala de emergência. Tosse, queda transitória de saturação de oxigênio e dificuldade de progredir a cânula através da laringe foram as principais complicações do método, mas não impediram a intubação. CONCLUSÃO: A FBI seguindo protocolo de sedação consciente com midazolam e fentanil é eficiente e segura no manejo de pacientes com via aérea difícil.


BACKGROUND AND OBJECTIVE: To describe the effi cacy and safety of a fl exible bronchoscopy intubation (FBI) protocol in patients with diffi cult airway. METHOD: We reviewed the medical records of patients diagnosed with diffi cult airway who underwent fl exible bronchoscopy intubation under spontaneous ventilation and sedation with midazolam and fentanyl from March 2009 to December 2010. RESULTS: The study enrolled 102 patients, 69 (67.7%) men and 33 (32.3%) women, with a mean age of 44 years. FBI was performed in 59 patients (57.8%) with expected diffi cult airway in the operating room, in 39 patients (38.2%) in the Intensive Care Unit (ICU), and in 4 patients (3.9%) in the emergency room. Cough, decrease in transient oxygen saturation, and diffi cult progression of the cannula through the larynx were the main complications, but these factors did not prevent intubation. CONCLUSION: FBI according to the conscious sedation protocol with midazolam and fentanyl is effective and safe in the management of patients with diffi cult airway.


JUSTIFICATIVA Y OBJETIVO: Describir un protocolo de intubación con broncoscopio fl exible (FBI, de flexible bronchoscopy intubation) en pacientes con la vía aérea difícil, su eficacia y seguridad. MÉTODOS: Describir un protocolo de intubación con broncoscopio fl exible (FBI, de flexible bronchoscopy intubation) en pacientes con la vía aérea difícil, su efi cacia y se Se revisaron las historias clínicas de pacientes diagnosticados con vía aérea difícil y que fueron sometidos a la broncoscopia fl exible para la intubación bajo ventilación espontánea y sedación con midazolam y fentanilo, de marzo de 2009 a diciembre de 2010. RESULTADOS: Fueron seleccionados 102 pacientes, 69 (67,7%) hombres y 33 (32,3%) mujeres, con una edad promedio de 44 años. En 59 pacientes con vía aérea difícil prevista (57,8%) la FBI se hizo en un centro quirúrgico; 39 (38,2%) ocurrieron en la Unidad de Cuidados Intensivos y cuatro casos (3,9%) en la sala de emergencia. La tos, la caída de saturación de oxígeno transitoria y la difi cultad para insertar la cánula a través de la laringe, fueron las principales complicaciones del método, pero no impidieron la intubación. CONCLUSIONES: La FBI, si secunda un protocolo de sedación consciente con midazolam y fentanilo, es efi ciente y segura en el manejo de pacientes con vía aérea difícil.


Subject(s)
Adult , Female , Humans , Male , Airway Management/methods , Bronchoscopes , Intubation, Intratracheal/methods , Airway Management/instrumentation , Equipment Design , Retrospective Studies